品牌:RETZ瑞茨/我們一直致力于流體控制和測控領域的持續創新,始于2005……
進口微彎型質量流量計產品用途 Product use
1.采用雙V 型流管設計,降低外界震動干擾影響,減少了安裝體積 Double V-shaped flow tube design is adopted to reduce the impact of external vibration interference and reduce the installation volume
2.提供質量流量、體積流量、密度、溫度測量參數,測量精度不受到溫度、壓力、密度、粘度影響Provide mass flow, volume flow, density, and temperature measurement parameters, and the measurement accuracy is not affected by temperature, pressure, density, and viscosity
3.V型結構設計壓力損失小,接液材質可更換耐腐蝕金屬哈氏合金,用于酸堿等腐蝕性介質測量 The V-shaped structure is designed with low pressure loss, and the liquid receiving material can be replaced with corrosion-resistant metal Hastelloy, which is used for measuring corrosive media such as acid and alkali
4.安裝簡單,沒有前后直管段要求,測量流體變化的時候無需重新標定 Simple installation, no requirements for front and rear straight pipe sections, and no need to recalibrate when measuring fluid changes
進口微彎型質量流量計 科里奧利 科氏力 V型質量流量計原理 Coriolis mass flowmeter principle
科里奧利質量流量計(Coriolis Mass Flowmeter)簡稱科氏力質量流量計,一個彎管道的兩端被固定,在兩個固定點的中間位置質量流量計原理圖.jpg給管道施加振動力(按管道的諧振頻率),使其以固定點為軸以其自然頻率u振動,當管道內沒有流體流動時,管道只受外加震動力作用,管道兩個半段振動方向相同,沒有相位差。當有流體流動時受管道內流動的介質質點科氏力Fc的影響,管道的兩個半段按相反的方向發生扭動,產生相位差,這一相位差同質量流量成正比,這就是科氏質量流量計的工作原理retz Coriolis Mass Flowmeter is referred to as Coriolis force mass flowmeter. Both ends of a curved pipe are fixed, and vibration force (based on the resonance frequency of the pipe) is applied to the pipe at the middle of the two fixed points, making it vibrate at its natural frequency u with the fixed point as the axis. When there is no fluid flow in the pipe, the pipe is only subjected to external vibration force, and the vibration directions of the two halves of the pipe are the same, without phase difference. When there is fluid flowing, influenced by the Coriolis force Fc of the medium particles flowing in the pipe, the two halves of the pipe twist in opposite directions, resulting in a phase difference that is proportional to the mass flow rate. This is the working principle of a Coriolis mass flowmeter
進口微彎型質量流量計 科里奧利 科氏力 V型質量流量計技術參數 Technical parameter
流量測量精度 0.1%、0.15%、0.2% 被測介質溫度 -200℃-350℃
重復性 0.05%-0.1% 適用環境溫度 -30~70℃
密度測量范圍 0<p<5g/cm3 測量管材質 316L,哈氏合金
密度測量精度 ±0.002g/cm3 工作壓力 常規4MPa,高壓可特殊訂制
溫度測量范圍 -200-350℃ 防爆型等級 Exd[ib]IICT1~T6Gb
溫度測量精度 ±1℃ 防護等級 IP67
輸出信號 4-20mA電流信號、0-10KHZ頻率信號、脈沖當量信號、RS485通訊信號、HART協議 |